| Model | PMU-10 | PMU-20 | PMU-30 | PMU-40 | PMU-60 | PMU-80 | PMU-100 | PMU-120 | PMU-160 | PMU-200 | 
| Capacity (VA) | 10kVA | 20kVA | 30kVA | 40kVA | 60kVA | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | 
| Power Rating (W) | 8kW | 16kW | 24kW | 32kW | 48kW | 64kW | 80kW | 96kW | 128kW | 160kW | 
| Input | ||||||||||
| Normal Voltage | 380/400/415Vac, (3Ph + N+PE) | |||||||||
| Voltage range | 208-478Vac | |||||||||
| Frequency Range | 40-70Hz | |||||||||
| Power Factor | ≥0.99 | |||||||||
| Harmonic Distortion (THDi) | 2% (100% non linear load) | |||||||||
| Bypass Voltage Range | Max. Voltage: +15% (optional +5%, +10%, +25%); Min. Voltage:-45% (optional -20%, -30%); Frequency protection range: ± 10% | |||||||||
| Generator Input | Supported | |||||||||
| Output | ||||||||||
| Rated Voltage | 380/400/415Vac, (3Ph+N+PE) | |||||||||
| Power Factor | 0.8/0.9(customisable) | |||||||||
| Voltage Regulation | ± 2% | |||||||||
| Frequency | Line mode: ± 1%/± 2%/±4%/±5%/±10% of the rated frequency (optional); Batt.mode: (50/60±0.2%)Hz | |||||||||
| Crest factor | 3:1 | |||||||||
| Harmonic distortion (THD) | ≤2% with linear load,≤5% with non linear load | |||||||||
| Efficiency | 94,5% | 95,5% | ||||||||
| Battery | ||||||||||
| Battery voltage | Standard unit: ±216Vdc; Long run unit optional voltage: ±192V/±204V/±216V/±228V/±240Vdc | |||||||||
| Capacity ( standard unit) | 12V/38Ah | |||||||||
| Charge Current (A) | Standard: 5.7A; Long Run: Max 6A | Max 12A | Max 18A | Max 24A | Max 30A | Max 36A | ||||
| System | ||||||||||
| Transfer time | 0ms | |||||||||
| Overload | Line mode: load ≤ 110%: 60min; ≤125%: 10min; ≤150%: 1min; ≥150% shut down UPS immediately Batt. mode: load ≤ 110%: 10min; ≤125%: 1min; ≤150%: 5s; ≥150% shut down UPS immediately | |||||||||
| Breaker | 20A | 40A | 50A | 80A | 100A | 125A | 80A | 100A | 100A | 125A | 
| Short Circuit | Hold whole system | |||||||||
| Overheat | Line mode: switch to bypass; backup mode: shut down UPS immediately | |||||||||
| Low battery voltage | Alarm and switch off | |||||||||
| Self-diagnostics | Shut down UPS immediately | |||||||||
| Comms & Management | ||||||||||
| Ports | RS232, RS485, Parallel, Intelligent slot, Relay card (optional), SNMP card (optional) | |||||||||
| Software | Windows 95/98/NT/2000/XP/Vista/7, Windows Server 2003/2008 Linux Debian, Redhat, Fedora, Suse, Ubuntu, CentOS, Novell, Mac, FreeBSD | |||||||||
| LCD | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature | |||||||||
| LED | Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault | |||||||||
| Options | Harmonic filter, SNMP adapter, Battery temperature sensor, Manual Bypass | |||||||||
| Environment | ||||||||||
| Operating temperature | 0 – 40°C | |||||||||
| Humidity | 0 ~95% non-condensing | |||||||||
| Storage temperature | -25°C – 55°C | |||||||||
| Noise | Complies with EN62040-2 | |||||||||
| Physical characteristics | ||||||||||
| Net (kg) | 123 | 125 | 126 | 164 | 166 | 195 | 286 | 317 | 348 | 355 | 
| Dimension (W x D x H) | 600 x 780 x 1200 | 600 x 780 x 1600 | ||||||||
| Safety & EMC CE, EN/IEC 62040-2, EN/IEC 62040-1-1 | ||||||||||
30kVA UPS with standard run 32P50A (PMU-30)
PMU-30
PMU series
New generation of ON-LINE double conversion digital UPS with DSP control
Advanced IGBT rectifier for low THD and high PF
30kVA UPS with standard run 32P50A (PMU-30)
Features
- True online double conversion UPS with DSP control
- High power density up to 200kVA
- Superior overload capability
- Unity power factor and low input distortion
- Output power factor at 0.8 (0.9pf is customisable)
- Wide input voltage and frequency windows
- Parallel redundancy of up to 4 units
- Includes internal Static and Manual bypass
- Modular design allows for easy service and maintenance
- Easy-to-operate LCD display for user-friendly operation
- Eco mode for energy saving
- Common or separate battery bank
- Programmable battery voltage from 192Vdc to 240Vdc
- Powerful charger built in
- Intelligent charge modes with smart charge current adjustment
- Programmable control and monitoring software via RS232
- Versatile communication interface options for various applications
- Megatec & MODBUS protocols supported